First, we need to generate our Telegraf config. This means we can use our Telegraf client to directly interface with Kepware. Under the hood, Kepware is built on top of an OPC UA server.
#Opc server kepware drivers
Refer to the article Uninstall or Repair National Instruments Software or Drivers in Windows if needed. In its infancy, OPC UA was primarily used to connect devices such as PLC’s to SCADA (Supervisory Control and Data Acquisition) systems.
#Opc server kepware install
#Opc server kepware serial
For that, refer to the OPC Foundation document Using OPC via DCOM with Microsoft XP Service Pack 2. Though the document is for Windows XP Service Pack 2, in the case of newer operating system as Windows 7, 8 or 10, mainly the UI appearance has changed. Kepware - Allen-Bradley OPC Server Suite Includes one year Support and Maintenance and ControlLogix Ethernet OPC Server, ControlLogix Unsolicited OPC Server, DF1, Data Highway Plus OPC Server, PLC5/SLC505 Ethernet OPC Server, Unsolicited Ethernet, Micro800 Ethernet, and Micro800 Serial Drivers. A CLSID is similar to your own government-issued identification, such as a Social Security Number (SSN) or Social Insurance Number (SIN), which identifies a specific.

The CLSID is a type of Globally Unique Identifier (GUID), which is a 128-bit number that identifies an application.

To communicate between different computers using OPC, we need to make sure that the DCOM settings are set to allow remote access and that the firewall is not blocking that communication. DCOM settings are security settings for the technology that OPC is built on.
#Opc server kepware password
Delete the default Username and Password fields. The default KEPServerEX UA port is 49320. If KEPServerEX is installed on the local machine use the actual IP address of the machine. Check whether the NI System Web Server, NI Variable Engine, NI Application Web Server, and OPCEnum services are started. Click Create new OPC Server Connection Choose OPC-UA Connection from the list of connection types.

#Opc server kepware driver
So if you have the choice, use a OPC UA server, or use a direct PLC driver that matches your PLC. zenon features an OPC UA client that can be used with any OPC UA server. In case of an OPC UA server, there is no issue at all to use a remote connection. One Year Support and Maintenance Agreement Mandatory at Time of Purchase (Sold Separately). OPC DA over DCOM has many issues and is a burden to configure correctly.Ĭonfiguring OPC over DCOM could make your system vulnerable to security hazards. I strongly recommend NOT to use a remote OPC DA server on a different PC than the zenon runtime. KEPServer is the leading OPC Server providing unsurpassed industrial connectivity with over 100 down loadable device drivers that. Generally, a direct connection to the PLC, without a third-party OPC server should always to be preferred! zenon offers over 300 connections to different PLCs.

Or use the zenon server and the OPC server on the same PC, and another zenon runtime as a client on another PC. In regard to the OPC DA 2.0 topic, it is recommended to use the zenon runtime and the OPC server on the same PC. As a server, it can collect, organize, and link data from other OPC servers and then offer that data to an OPC/DDE client. In this case, the PC starts as a client and attempts to connect to the server. ThingWorx Kepware Server löst einen der kompliziertesten und kritischsten Aspekte Ihres IIoT- oder Industrie 4.0-Projekts: Die Verbindung mit den Geräten, die die Produktion steuern. So for your project, the option "network active" is probably set, and the name of the server is not the name of the PC that you started the runtime on. ThingWorx® Kepware® Server bietet eine einzige, robuste Schnittstelle zu Industriedaten und genießt seit fast 25 Jahren das Vertrauen von Betrieb und Technik. A blue square normally signals "no connection to the runtime server".